Method development for determination of trace amounts of palladium in environmental water samples by ICP-MS/MS after pre-concentration on thiol-functionalized MCM-41 materials
Authors:
- Barbara Leśniewska,
- Żaneta Arciszewska,
- Agata Wawrzyńczak,
- Sylwia Jarmolińska,
- Izabela Justyna Nowak,
- Beata Godlewska-Żyłkiewicz
Abstract
The anthropogenic cycle of Pd in the environment, its fate and impact is still unknown due to limitations of measurement techniques. For separation and pre-concentration of Pd(II) ions, mesoporous silica materials MCM-41 were synthesized and functionalized with different amounts of 3-mercaptopropyltrimethoxysilane (MPTMS) by co-condensation and grafting methods. The structural and textural properties of materials were characterized using XRD, TEM, SEM and BET techniques. The results proved that functionalization with thiol groups did not significantly affect structural and textural parameters of synthesized sorbents. The Pd(II) ions were quantitatively retained on sorbents functionalized by grafting in acidic solutions (pH 2), efficiently eluted with 0.1 mol L−1 thiourea solution in 1 mol L−1 HCl and determined by electrothermal atomic absorption spectrometry (ETAAS). The limit of detection (LOD) of the developed SPE ETAAS method was 0.06 ng mL−1, and the pre-concentration factor was 30. For analysis of Pd in environmental water samples inductively coupled plasma mass spectrometry (ICP-MS) in MS/MS mode was used. Spectral interferences on 105Pd caused by the presence of Sr in water samples were eliminated using helium (5 mL min−1) or ammonia (7 mL min−1) gas in collision/reaction cell. The developed SPE ICP-MS method is characterized by good selectivity in the presence of interfering elements and chloride ions and detection limit of 0.0002 ng mL−1. Its accuracy was confirmed by analysis of spiked water samples. The application of ICP-MS together with efficient separation/pre-concentration of analyte on thiol-functionalized MCM-41 sorbents allows to determine Pd in environmental water samples at pg mL−1 level
- Record ID
- UAMab6314e71a4047b7968ed5ca0ce7a3e6
- Author
- Journal series
- Talanta, ISSN 0039-9140, e-ISSN 1873-3573
- Issue year
- 2020
- Vol
- 217
- Pages
- 1-12
- Article number
- 121004
- Keywords in English
- Collision/reaction cell Spectral interferences Solid phase extraction Mesoporous silica materials Sea water Road runoff Waste water
- ASJC Classification
- DOI
- DOI:10.1016/j.talanta.2020.121004 Opening in a new tab
- URL
- https://www.sciencedirect.com/science/article/abs/pii/S0039914020302952 Opening in a new tab
- Language
- (en) English
- Score (nominal)
- 100
- Score source
- journalList
- Score
- = 100.0, 21-05-2022, ArticleFromJournal
- Publication indicators
- = 8; = 2; : 2016 = 1.270; : 2019 (2 years) = 5.339 - 2019 (5 years) =4.711
- Uniform Resource Identifier
- https://researchportal.amu.edu.pl/info/article/UAMab6314e71a4047b7968ed5ca0ce7a3e6/
- URN
urn:amu-prod:UAMab6314e71a4047b7968ed5ca0ce7a3e6
* presented citation count is obtained through Internet information analysis and it is close to the number calculated by the Publish or PerishOpening in a new tab system.